عنوان مقاله :
بررسي ميزان پليمريزاسيون يك رزين باندينگ آزمايشگاهي كيور شده با LED توسط دستگاه DSC
عنوان به زبان ديگر :
Evaluation of polymerization of an experimental bonding resin cured with light emitting diodes using Differential Scanning Calorimetry
پديد آورندگان :
جعفرزاده كاشي، طاهره السادات نويسنده دانشگاه علوم پزشكي تهران,دانشكده دندانپزشكي، مركز تحقيقات دندانپزشكي; Jafarzadekashi, T , عرفان، محمد نويسنده دانشگاه علوم پزشكي شهيد بهشتي,; Erfan, M , ميرزايي، مرضيه نويسنده ; Mirzaie, M , كلباسي، سلمه نويسنده ; Kalbasi, S
اطلاعات موجودي :
فصلنامه سال 1388 شماره 58
رتبه نشريه :
علمي پژوهشي
تعداد صفحه :
8
از صفحه :
41
تا صفحه :
48
كليدواژه :
باندينگ , ميزان پليمريزاسيون , ديودهاي منتشركننده نور (DSC) Differential Scanning Calorimetry , (LED)
چكيده لاتين :
Background and Aim: Extent of polymerization (Ep) is the rate at which methacrylate C=C bonds are converted to aliphatic C-C bonds. The higher the Ep value, the better the polymerization of the polymer. If the polymer dose not polymerize sufficiently, it could have destructive effects e.g. releasing monomer, initiator, free radical or insufficient polymerization of hybrid layer. Therefore, measuring the Ep value is very important. Light-emitting diodes (LEDs) are becoming increasingly popular in dental practice as they have a long life expectancy. LEDs do not generate infrared wavelength, and have a constant light output. Therefore, comparison of LED and Quartz tungsten halogen (QTH) from the point of Ep is important. Differential Scanning Calorimetry (DSC) is a proper tool for determining the Ep value, monitoring the process of reaction and reaction kinetics. The aim of this study was to measure the Ep value of a dental bonding containing camphorquinone/amine photoinitiator which were cured by LED and QTH using DSC. Materials and Methods: In this experimental study, 2.5 mg of bonding material were placed in DSC aluminum pans. Two different light cures, LED & QTH (Coltene Company Coltolux ®75 LED Curing Light), were used in this study. The light guide was positioned at a distance of 9mm from the base of the sample chamber. Each sample was photopolymerized for 30 seconds, and the DSC curves were obtained after 100 seconds from initiation of photopolimerization of each sample, at both 23°C and 37°C. The heat of photopolymerization (AH) was calculated from the area under the peak of the differential temperature curve. Five samples were used for each condition. The data was analyzed by two-way ANOVA. Results: There was highly significant difference between two temperatures in the experimental bonding (pvalue<0.001). Representative DSC curves showed the same kinetic behavior for LED and QTH. Conclusion: The results revealed that the Ep generated by high power density QTH was the same as that of produced by second generation of LED.
سال انتشار :
1388
عنوان نشريه :
دندانپزشكي دانشگاه علوم پزشكي تهران
عنوان نشريه :
دندانپزشكي دانشگاه علوم پزشكي تهران
اطلاعات موجودي :
فصلنامه با شماره پیاپی 58 سال 1388
كلمات كليدي :
#تست#آزمون###امتحان