شماره ركورد :
429849
عنوان مقاله :
بررسي استحكام باند برشي كامپوزيت به فلزات غيرقيمتي با آماده سازي هاي سطحي مختلف
عنوان به زبان ديگر :
Evaluation of shear bond strength of composite resin to nonprecious metal alloys with different surface treatments
پديد آورندگان :
ياسيني، اسماعيل نويسنده دانشگاه علوم پزشكي تهران,دانشكده دندانپزشكي، مركز تحقيقات دندانپزشكي; Yassini, E , الماسي، صنم نويسنده ; Almasi, S
اطلاعات موجودي :
فصلنامه سال 1386 شماره 52
رتبه نشريه :
علمي پژوهشي
تعداد صفحه :
8
از صفحه :
193
تا صفحه :
200
كليدواژه :
ترميم فلز سراميك , آلياژهاي غيرقيمتي , مواد ترميم پرسلن
چكيده لاتين :
Background and Aim: Replacing fractured ceramometal restorations may be the best treatment option, but it is costly. Many different bonding systems are currently available to repair the fractured ceramometal restorations. This study compared the shear bond strength of composite to a base metal alloy using 4 bonding systems. Materials and Methods: In this experimental in vitro study, fifty discs, casted in a Ni-Cr-Be base metal alloy (Silvercast, Fulldent),were ground with 120, 400 and 600 grit sandpaper and divided equally into 5 groups receiving 5 treatments for veneering. Conventional feldspathic porcelain (Ceramco2, Dentsply Ceramco) was applied on control group (PFM or group 1) and the remaining metal discs were air- abraded for 15 seconds with 50 Mm aluminum oxide at 45 psi and washed for 5 seconds under tap water. Then the specimens were dried by compressed air and the groups were treated with one of the bonding systems as follows: All-Bond 2 (AB), Ceramic Primer (CP), Metal Primer II (MP) and Panavia F2 (PF). An opaque composite (Foundation opaque) followed by a hybrid composite (Gradia Direct) was placed on the treated metal surface and light cured separately. Specimens were stored in distilled water at 37°C and thermocycled prior to shear strength testing. Fractured specimens were evaluated under a stereomicroscope. Statistical analysis was performed with one way ANOVA and Tukey HSD tests. P<0.05 was considered as the level of significance. Results: Mean shear bond strengths of the groups in MPa were as follows: PFM group 38.6±2, All-Bond 2 17.06±2.85, Ceramic Primer 14.72±1.2, Metal Primer II 19.04±2.2 and Panavia F2 21.37±2.1. PFM group exhibited the highest mean shear bond strength and Ceramic Primer showed the lowest. Tukeyʹs HSD test revealed the mean bond strength of the PFM group to be significantly higher than the other groups (P<0.001). The data for the PF group was significantly higher than AB and CP groups (P<0.05) and the shear bond strength of the MP group was higher than CP group, but was not significantly different from AB (P>0.05). Conclusion: Based on the results of this study, the most reliable treatment for fractured metal-ceramic restorations would be the replacement of the restoration. If this is not possible, adhesive resin cements containing filler and phosphate-based monomers (especially MDP) such as Panavia F2 could be recommended for bonding composite to base metal alloys.
سال انتشار :
1386
عنوان نشريه :
دندانپزشكي دانشگاه علوم پزشكي تهران
عنوان نشريه :
دندانپزشكي دانشگاه علوم پزشكي تهران
اطلاعات موجودي :
فصلنامه با شماره پیاپی 52 سال 1386
كلمات كليدي :
#تست#آزمون###امتحان
لينک به اين مدرک :
بازگشت