شماره ركورد :
429927
عنوان مقاله :
بررسي دقت تكنيك راديوگرافي پانوراميك، راديوگرافي پانوراميك به همراه لمس ناحيه و تكنيك tube shift در تعيين موقعيت دندان كانين نهفته فك بالا
عنوان به زبان ديگر :
Accuracy of panoramic, panoramic with palpation and tube shift technique to localize maxillary impacted cuspid
پديد آورندگان :
گودرزي پور، داريوش نويسنده دانشگاه علوم پزشكي تهران,دانشكده دندانپزشكي; GoodarziPour, D , سعيدي، آكام نويسنده ; Saeedi, A , بهرامي، نغمه نويسنده ; Bahrami, N
اطلاعات موجودي :
فصلنامه سال 1388 شماره 60
رتبه نشريه :
علمي پژوهشي
تعداد صفحه :
7
از صفحه :
99
تا صفحه :
105
كليدواژه :
كانين نهفته , تعيين موقعيت , راديوگرافي , پانوراميك , لمس
چكيده لاتين :
Background and Aim: Impaction of maxillary cuspids is the most common after third molars with 1% to 3% prevalence. Localization of these impacted teeth may affect orthodontic or surgical treatment plan. Therefore, different techniques have been introduced to localize impacted canines. The present study was conducted to compare the accuracy of panoramic, tube shift and panoramic plus palpation in determination of the position of maxillary impacted canine. Materials and Methods: 47 patients (20 females, 27 males) with the age of more than 12 years (mean age of 25.4 years old) whom referred to Dental School, Tehran University of Medical Sciences, with at least one impacted maxillary canine included. An oral and maxillofacial radiologist localized impacted canine first by using panoramic then tube shift technique blindly. After that, an oral and maxillofacial surgeon localized the canine by panoramic and palpation of the area before surgery. Data obtained from radiologist and surgeon were compared with true location of canine after surgery. Statistical analysis was done using sensitivity and specificity. Results: Among total 47 impacted maxillary canines, 11 cases (23.4%) showed buccal impactions and 36 cases (76.6%) palatal impactions. Sensitivity (ability of technique to localize palatal impaction) of all of the techniques were same (100%) but specificity (ability of technique to localize buccal impaction) of tube shift (100%) was more than two others (0%). Conclusion: The tube shift technique was the most accurate technique to localize maxillary unerupted canines compared to the others. Due to the ability of panoramic and panoramic with palpation in prediction of palatal canine impactions and failure of these techniques to predict buccal impactions, both methods are not suitable in localization of impacted maxillary canines and they must be used as adjunctive techniques.
سال انتشار :
1388
عنوان نشريه :
دندانپزشكي دانشگاه علوم پزشكي تهران
عنوان نشريه :
دندانپزشكي دانشگاه علوم پزشكي تهران
اطلاعات موجودي :
فصلنامه با شماره پیاپی 60 سال 1388
كلمات كليدي :
#تست#آزمون###امتحان
لينک به اين مدرک :
بازگشت