اصلاح آلودگي متقابل در تصويربرداري اسپكت همزمان تاليوم - تكنسيوم از قلب با روش تلفيقي - تفاضلي
عنوان به زبان ديگر :
Compensation of Cross-Contamination in Simultaneous 2oiT1/»9mTc Myocardial Perfusion SPECT Imaging
پديد آورندگان :
كلانتري، فراز نويسنده دانشكده علوم پزشكي،دانشگاه علوم پزشكي تربيت مدرس Kalantari, Faraz , رجبي، حسين نويسنده گروه فيزيك پزشكي، دانشكده پزشكي، دانشگاه تربيت مدرس Rajabi, Hossein , يعقوبي، ناهيد نويسنده Yaghoobi, Nahid , بيطرفان رجبي، احمد نويسنده دانشكده علوم پزشكي،دانشگاه علوم پزشكي تربيت مدرس Bitarafan, Ahmad
اطلاعات موجودي :
فصلنامه سال 1388 شماره 24
رتبه نشريه :
علمي پژوهشي
تعداد صفحه :
14
از صفحه :
58
تا صفحه :
71
كليدواژه :
آلودگي متقابل , تاليوم , تكنسيوم، NCAT , SimSET , اسپكت همزمان , تلفيق
چكيده لاتين :
Introduction: It is a common protocol to use 201T1 for the rest and 99mTc for the stress cardiac SPECT imaging. Theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. However, a potential limitation is the cross- contamination of scattered photons from "mTc and collimator X-rays into the 201T1 energy window. We used a middle energy window method to correct this cross-contamination. Material and Methods: Using NCAT, a typical software torso phantom was generated. An extremely thin line source of "mTc activity was placed inside the cardiac region of the phantom and no activity in the other parts. The SimSET Monte Carlo simulator was used to image the phantom in different energy windows. To find the relationship between projections in different energy windows, deconvolution theory was used. We investigated the ability of the suggested functions in three steps: Monte Carlo simulation, phantom experiment and clinical study. In the last step, SPECT images of eleven patients who had angiographic data were acquired in different energy windows. All of these images were compared by determining the contrast between a defect or left ventricle cavity and the myocardium. Results: We found a new 2D kernel which had an exponential pattern with a much higher center. This function was used for modeling "mTc down scatter distribution from the middle window image. X-ray distribution in the 201T1 window was also modeled as the "mTc photopeak image convolved by a Gaussian function. Significant improvements in the contrasts of the simultaneous dual 201T1 images were found in each step before and after reconstruction. In comparison with other similar methods, better results were acquired using our suggested functions. Conclusion: Our results showed contrast improvement in thallium images after correction, however, many other parameters should be evaluated for clinical approaches. There are many advantages in simultaneous dual isotope imaging. It halves imaging time and reduces patient waiting time and discomfort. Identical rest/stress registration of images also facilitates physicistsʹ motion or attenuation corrections and physiciansʹ image interpretation.
سال انتشار :
1388
اطلاعات موجودي :
فصلنامه با شماره پیاپی 25 سال 1388
كلمات كليدي :
#تست#آزمون###امتحان
لينک به اين مدرک :
بازگشت