عنوان مقاله :
Immunohistochemical Study of Spinal Motor NeuronsFollowing Sciatic Nerve Repair in Adult Rat
عنوان به زبان ديگر :
Immunohistochemical Study of Spinal Motor Neurons Following Sciatic Nerve Repair in Adult Rat
پديد آورندگان :
Shariati، Tabandeh نويسنده Iran Medical University,Anatomy Department Faghihi, A , Bahadori، Mohammad Hadi نويسنده Roozbehi, A , Azizzade Delshad، Alireza نويسنده Shahed University,Anatomy Department Azizzade Delshad, A.R. , Faghihi، Abolfazl نويسنده Iran Medical University,Anatomy Department Bahadori, M.H. , Roozbehi، Amrollah نويسنده Yasuj University of Medical Sciences, Shariati, T
كليدواژه :
Sciatic nerve repair , PVDF , Nerve guidance channel , Spinal MotorNeurons , NGF
چكيده فارسي :
Introduction: Epineural suture and autologous graft are two routinetechniques in peripheral nerve surgery. However, their efficiency can behighly limited depending on the type of lesion and the gap between twonerve stumps and because of deficient proper nerve donors. So muchinterest has been focused on the development of alternative instruments forbridging the nerve gaps. In the present study, we have used chargedpolyvinelidene fluoride (PVDF) tube filled with nerve growth factor (NGF) andcollagen gel as a substitute for nerve autograft and compared the resultswith other current surgical techniques. We studied the changes of spinalmotoneurons to evaluate the effect of repairing techniques.Material and Methods: In this study, 30 male Wistar rats weighing 200-250g were divided randomly in five groups: axotomy, epineural suture, autograft,nerve guidance channel, and sham operation. In all experimental groups, theleft sciatic nerve was transected at mid-thigh level. The nerve was notrepaired in axotomy group. In epineural suture group, it was sutured end-toend.In autograft group, a 10 mm piece of nerve was rotated 180° andsutured again in the nerve gap. Finally, in nerve guidance channel group, apiece of PVDF tube containing NGF7s (100 ng/ml) and collagen gel (1.28mg/ml) was replaced in the gap. After one week, one month, and twomonths, L4-6 segments of spinal cord were removed and 5 μm paraffinsections were prepared for bax immunohistochemical study. In all groupscontralateral spinal cord was used as the control. The proportion of Baxpositiveapoptotic motoneurons was studied in all groups to evaluate theefficiency of different repairing techniques.Results: Mean percentage of Bax-positive neurons to the total number ofmotor neurons in left side was analyzed. One way ANOVA showedsignificant difference after two months. LSD post hoc test showed that meanpercentage of Bax-positive neurons in axotomized group was significantlyhigher compared to other surgical groups (p<0.05).The number of apoptotic neurons after one week, one month and twomonths in each type of surgical approach showed no significant differencebetween one week and one month and between one month and two months.Comparison of motoneuron population in left side (experimental) with rightside (control) showed no significant differences after one week, butsignificant differences were seen (p<0.01) after one month and two months.In sham group, no Bax-positive neuron was found after one week, onemonth, and two months.Conclusion: A PVDF tube filled with NGF and collagen gel can be used asa proper substitute for autografts and protect motoneurons followingperipheral nerve injury.
چكيده لاتين :
Introduction: Epineural suture and autologous graft are two routine techniques in peripheral nerve surgery. However, their efficiency can be highly limited depending on the type of lesion and the gap between two nerve stumps and because of deficient proper nerve donors. So much interest has been focused on the development of alternative instruments for bridging the nerve gaps. In the present study, we have used charged polyvinelidene fluoride (PVDF) tube filled with nerve growth factor (NGF) and collagen gel as a substitute for nerve autograft and compared the results with other current surgical techniques. We studied the changes of spinal motoneurons to evaluate the effect of repairing techniques. Material and Methods: In this study, 30 male Wistar rats weighing 200-250 g were divided randomly in five groups: axotomy, epineural suture, autograft, nerve guidance channel, and sham operation. In all experimental groups, the left sciatic nerve was transected at mid-thigh level. The nerve was not repaired in axotomy group. In epineural suture group, it was sutured end-to-end. In autograft group, a 10 mm piece of nerve was rotated 180° and sutured again in the nerve gap. Finally, in nerve guidance channel group, a piece of PVDF tube containing NGF7s (100 ng/ml) and collagen gel (1.28 mg/ml) was replaced in the gap. After one week, one month, and two months, L4-6 segments of spinal cord were removed and 5 Mm paraffin sections were prepared for bax immunohistochemical study. In all groups contralateral spinal cord was used as the control. The proportion of Bax-positive apoptotic motoneurons was studied in all groups to evaluate the efficiency of different repairing techniques.
Results: Mean percentage of Bax-positive neurons to the total number of motor neurons in left side was analyzed. One way ANOVA showed significant difference after two months. LSD post hoc test showed that mean percentage of Bax-positive neurons in axotomized group was significantly higher compared to other surgical groups (p<0.05).
The number of apoptotic neurons after one week, one month and two months in each type of surgical approach showed no significant difference between one week and one month and between one month and two months. Comparison of motoneuron population in left side (experimental) with right side (control) showed no significant differences after one week, but significant differences were seen (p<0.01) after one month and two months. In sham group, no Bax-positive neuron was found after one week, one month, and two months.
Conclusion: A PVDF tube filled with NGF and collagen gel can be used as a proper substitute for autografts and protect motoneurons following peripheral nerve injury.
كلمات كليدي :
#تست#آزمون###امتحان