شماره ركورد :
516416
عنوان مقاله :
حذف سيانيد از رسوب‌هاي سد باطله به‌وسيله فن‌آوري الكتروكينتيك
عنوان فرعي :
Cyanide Removal From Contaminated Sediment of Tailing Dam by Electrokinetic Technology
پديد آورندگان :
خدادادي، احمد نويسنده Khodadadi, A , گنجي‌دوست، حسين نويسنده Ganjidoust, H. , بني‌مصطفي عرب، ايزد نويسنده Bani Mostafa, E.
اطلاعات موجودي :
فصلنامه سال 1389 شماره 0
رتبه نشريه :
علمي پژوهشي
تعداد صفحه :
9
از صفحه :
47
تا صفحه :
55
كليدواژه :
Contaminated soils , Electrokinetic remediation , Gold mine , Tailing dam , الكتروكينتيك , سد باطله , سيانيد , پالايش خاك , Cyanide
چكيده فارسي :
- پاكسازي خاك آلوده به سيانيد با روش‌هاي مختلف از جمله اكسيداسيون،خاكشويي، تجزيه بيولوژيكي و روش الكتروكينتيك انجام مي‌شود. استفاده از روش الكتروكينتيك براي حذف سيانيد تاكنون كم‌تر استفاده شده است. بنابراين، اين تحقيق براي بررسي كارايي اين روش در خاك با درصد رس بالا و نفوذپذيزي پايين انجام شد. در روش الكتروكينتيك با قرار دادن دو الكترود داخل خاك و برقراري جريان مستقيم، يون CN– كه تحت يك ميدان الكتريكي قرار گرفته است به سمت قطب مثبت (آند) مهاجرت كرده و خاك پالايش مي‌شود. در اين پژوهش، پاكسازي خاك سد باطله معدن طلاي تكاب از نوع رس (CL) با غلظت سيانيد 420 ميلي‌گرم بر خاك خشك با استفاده از محلول‌هاي آب مقطر و سود 1 مولار در آند، مورد بررسي قرار گرفت. مايع مورد استفاده در كاتد آب مقطر بود. خاك مورد نظر با رطوبت بهينه با استفاده از جريان مستقيم با شيب ولتاژV/cm 1 وV/cm 5/1 با زمان عبور جريان به مدت 7 و 14 روز آزمايش شد. در انتهاي دوره، راندمان حذف سيانيد از خاك، pH خاك،رطوبت، جريان الكترواسمز و آمپراژ روزانه اندازه‌گيري شد. نتايج اين تحقيق نشان مي‌دهد كه سيانيد در مدت 7 و 14 روز به ترتيب با راندمان 65 و80 درصد حذف شده است.pH خاك از ميزان اوليه (حدود 83/8) به 1 تا 2 در نزديك‌اند و12 تا 13 در مجاورت كاتد تغيير كرد. تحليل نتايج نشان داد كه مهاجرت سيانيد به سمت قطب مثبت (آند) و تغييرات pH، عوامل اصلي در تعيين راندمان حذف سيانيد است.
چكيده لاتين :
There are known techniques for cyanide remediation from contaminated soil such as soil washing, soil oxidation and biological degradation. However, there is very little research for electrokinetic remediation of cyanide from soil. This study investigates the application of electrokinetic remediation to contaminated soil with high clay content and low coefficient of permeability. The experiments were conducted with two electrodes as cathode and anode poles, which were placed inside the soil using the direct electrical current. Thus cyanide ions were transported to the anode pole and caused the remediation of the soil. The contaminated soil from tailing dam of Takab gold processing plant was used. Contaminated soil with the concentration of 420 mg/kg, distilled water and NaOH were employed in the electrokinetic cell. The experiments were conducted on the optimum moisture content of clayed soil at two voltage gradients (1.0 and 1.5 VDC/cm for the duration of 7 and 14 days) in order to assess the effect of voltage gradient when employing 1M NaOH solutions and distilled water at the anode pole. For each test, cyanide removal efficiency, the pH of the soil, moisture content, electrical conductivity and the electrical current and flow were determined. The measurements were conducted for the entire duration of electrokinetic experiments and at the end of the test. The results indicated that the cyanide removal obtained in 7 and 14 days was approximately 65% and 80%, respectively. The results also showed the pH of the soil was changed from 8.83 to 1-2 for the anode and to 12-13 for the cathode pole. The cyanide transported to the cathode and the pH were the most important dominant factors for cyanide remediation.
سال انتشار :
1389
عنوان نشريه :
مهندسي عمران مدرس
عنوان نشريه :
مهندسي عمران مدرس
اطلاعات موجودي :
فصلنامه با شماره پیاپی 0 سال 1389
كلمات كليدي :
#تست#آزمون###امتحان
لينک به اين مدرک :
بازگشت