شماره ركورد :
538191
عنوان مقاله :
تاثير مكانيسم گير در تري اختصاصي بر دقت ابعادي كست‌هاي اصلي حاصل از قالب‌هاي آلژينات
عنوان فرعي :
Effect of retention features in custom trays on dimensional accuracy of master casts made from alginate impressions
پديد آورندگان :
مشرف ، رامين نويسنده Associate Professor, Torabinejad Dental Research Center, Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Is Mosharraf, Ramin , زارعي ، زينب نويسنده Zareie, Zeynab
اطلاعات موجودي :
فصلنامه سال 1390 شماره 0
رتبه نشريه :
علمي پژوهشي
تعداد صفحه :
10
از صفحه :
676
تا صفحه :
685
كليدواژه :
دنداني , آلژينات ها , رو شهاي قالب گيري , مواد قالب گيري
چكيده فارسي :
چكيده مقدمه: چسبندگي كامل مواد قالب‌گيري به تري براي جلوگيري از جدا شدن آن‌ها در موقع خروج قالب از دهان و اطمينان از جهت‌گيري انقباض پليمريزاسيون اين مواد به طرف تري اهميت زيادي دارد. هدف از اين پژوهش، بررسي دقت ابعادي كست‌هاي اصلي حاصل از دو نوع ماده قالب‌گيري آلژيناتي با دو روش گير ماده قالب‌گيري (چسب و سوراخ) بود. مواد و روش‌ها: در اين مطالعه تجربي- آزمايشگاهي، هشت گروه يازده‌تايي با قالب‌گيري از يك مدل فلزي داراي سه ميله عمودي و ريختن آن‌ها با گچ استون تهيه شد. سه متغير شامل نوع ماده قالب‌گيري هيدروكلوييد برگشت ناپذير، وجود سوراخ در تري قالب‌گيري و كاربرد چسب آلژينات مورد نظر بودند. فواصل مورد نظر توسط كوليس ديجيتالي با دقت 01/0 ± ميلي‌متر اندازه‌گيري شدند. تجزيه و تحليل آماري در سطح معنا‌داري 05/0 توسط آزمون‌هاي آماري آناليز واريانس، Kruskal–Wallis ، Whitney-Mann وآزمون t انجام شد. يافته‌ها: آزمون آماري ANOVA نشان داد كه گروه‌ها تنها در بعد عمودي (001/0 = p value) تفاوت معنا‌داري داشتند. اختلاف بين دو نوع تري (0001/0 p value < ) و دو نوع آلژينات تنها در بعد عمودي معنادار بود (011/0 = p value). با كاربرد چسب آلژينات در هيچ كدام از ابعاد تفاوت معناداري ديده نشد. ميانگين گروه‌هاي مورد بررسي در هر دو نوع تري در مقايسه با ابعاد الگوي فلزي، در تمام ابعاد تفاوت معناداري داشت. ميانگين گروه‌هاي آلژينات Iralgin، در هر سه بعد با ابعاد كست اصلي و در مورد آلژينات Xantalgin تنها در بعد طولي تفاوت معناداري داشت. ميانگين گروه‌هاي بدون چسب آلژينات در همه ابعاد با كست اصلي تفاوت معناداري داشتند. ميانگين گروه‌هاي داراي چسب آلژينات فقط در بعد عمودي تفاوت معناداري نداشتند. نتيجه‌گيري: بر اساس نتايج اين مطالعه تري سوراخ‌دار، آلژينات Xantalgin و استفاده از چسب آلژينات در هر سه بعد در مقايسه با گروه‌هاي متناظر، كست‌هاي دقيق تري به وجود آوردند. در صورت عدم استفاده از چسب آلژينات، با انتخاب تري سوراخ‌دار مي‌توان دقت كست حاصل را افزايش داد؛ در صورت كاربرد چسب آلژينات با تري بدون سوراخ بهتر است از آلژينات Xantalgin استفاده شود، و در صورت استفاده از تري سوراخ‌دار و آلژينات Iralgin مي‌توان با كاربرد چسب آلژينات دقت كست حاصل را بيشتر كرد؛ اما اين كار در مورد آلژينات Xantalgin تاثيري ندارد. كليد واژه‌ها: دنداني، مواد قالب‌گيري، روش‌هاي قالب‌گيري، آلژينات‌ها.
چكيده لاتين :
Abstract Introduction: Complete adhesion of the impression materials to trays is important to prevent impression materials from being pulled away from trays during removed from the mouth and to ensure that the direction of polymerization shrinkage will be towards the tray. The aim of this study was to evaluate the effects of two retention features of custom trays (adhesive vs holes) on the dimensional accuracy of master casts made from two alginate impression materials. Materials and methods: In this in vitro study, 88 impressions were made in eight groups (n=11) of a stainless steel model with three index studs and then poured with a Type III dental stone. Three variables were considered: type of irreversible hydrocolloid material, retentive perforations in impression trays and application of a spray-on tray adhesive. The distances between the reproduced index studs were measured to ±0.01 mm with a digital caliper. Kruskal-Wallis and Mann-Whitney tests, ANOVA and t-test were used for data analysis (?=0.05). Results: ANOVA revealed significant differences between the groups only in the vertical dimension (p value = 0.001). There were significant differences between the two tray and alginate types only in the vertical dimension (p value < 0.001 and p value = 0.011). There were no significant differences between the adhesive and non-adhesive groups. There were significant differences in the means of all the dimensions of the two trays as compared with master model. Iralgin alginate group exhibited significant differences in the means of all the three variables compared to the main cast; Xantalgin alginate exhibited differences only in the longitudinal dimension. Non-adhesive group exhibited significant differences in all the three dimensions but the adhesive group did not reveal significant differences only in the vertical dimension. Conclusion: Perforated tray, Xantalgin alginate and use of adhesive produced more accurate casts in all the dimensions compared to corresponding groups. In cases in which an adhesive is not used dimensional accuracy will improve via perforated trays. By using an adhesive with non-perforated tray, Xantalgin alginate has more accurate results; use of an adhesive along with perforated trays produces better results with Iralgin alginate, but no improvements are achieved with Xantalgin. Key words: Alginates, Dental, Impression Materials, Impression Techniques.
سال انتشار :
1390
عنوان نشريه :
م‍ج‍ل‍ه‌ دان‍ش‍ك‍ده‌ دن‍دان‍پ‍زش‍ك‍ي‌ اص‍ف‍ه‍ان‌
عنوان نشريه :
م‍ج‍ل‍ه‌ دان‍ش‍ك‍ده‌ دن‍دان‍پ‍زش‍ك‍ي‌ اص‍ف‍ه‍ان‌
اطلاعات موجودي :
فصلنامه با شماره پیاپی 0 سال 1390
كلمات كليدي :
#تست#آزمون###امتحان
لينک به اين مدرک :
بازگشت