شماره ركورد :
618308
عنوان مقاله :
Comparison of temperature rise in silorane-based and methacrylate-based composites cured by LED and Argon laser
پديد آورندگان :
Hasani Tabatabaei ، Masomeh نويسنده Associate Professor, Department of Restorative Dentistry, School of Dentistry, Tehran University of Medical Sciences. Tehran, Iran , , Etrati Khosroshahi ، Mohammad نويسنده Professor, Department of Biomedical Engineering, Amirkabir University of Technology. Tehran, Iran , , Pahlavan ، Ayub نويسنده Associate Professor, Department of Restorative Dentistry, School of Dentistry, Tehran University of Medical Sciences. Tehran, Iran , , Arami، Sakineh نويسنده Assistant Professor, Department of Restorative Dentistry, School of Dentistry, Tehran University of Medical Sciences. Tehran, Iran , , Valizadeh ، Sara نويسنده Operative Dentist ,
اطلاعات موجودي :
فصلنامه سال 1391 شماره 83
رتبه نشريه :
علمي پژوهشي
تعداد صفحه :
7
از صفحه :
139
تا صفحه :
145
كليدواژه :
Filtek Silorane , Methacrylates , Polymerization , Temperature , Gas Laser
چكيده لاتين :
Abstract Background and Aim: Temperature rise occurs during photoactivation of dental composites due to the exothermic polymerization reaction and different curing units. The aim of this study was evaluation of temperature rise in two kinds of composites with different curing units. Materials and Methods: In this experimental study, five samples of each composite resin (Filtek Z250, Filtek P90) were placed in two-millimeter deep Teflon molds which were 4mm in diameter. Curing was done from top surface with LED, high power LED and argon laser and temperature was recorded by a thermometer placed under the samples. After reaching room temperature, samples were cured and the temperature was recorded again. The time of maximum temperature was also recorded. The data were analyzed by two-way ANOVA and Tukey HSD. Results: Composites and curing units had statistically significant influence on the temperature rise (p < 0.001) Silorane-based composites showed significantly higher temperature rise than methacrylate-based ones. A significantly lower rise in tempera-ture occurred when illuminationwas performed by argon laser. There was no signifi-cant difference in temperature rise between the two types of LEDs. The type of com-posite had no effect on the time of maximum temperature and in all samples the max-imum temperature was recorded at the beginning of irradiation. Conclusion: Silorane-based composites showed higher temperature rise than methacrylate-based ones. Argon laser revealed less heat than LEDs. The maximum temperature rise was recorded at the beginning of irradiation. Key Words: Polymerization - Temperature - Gas Laser - Filtek Silorane - Methacrylate s
سال انتشار :
1391
عنوان نشريه :
دندانپزشكي - جامعه اسلامي داندانپزشكان
عنوان نشريه :
دندانپزشكي - جامعه اسلامي داندانپزشكان
اطلاعات موجودي :
فصلنامه با شماره پیاپی 83 سال 1391
كلمات كليدي :
#تست#آزمون###امتحان
لينک به اين مدرک :
بازگشت