شماره ركورد :
641616
عنوان مقاله :
Micro-shear Bond Strength of a Nanofiller Bonding agent with and without Thermocycling in a Newly Invented Device
عنوان فرعي :
بررسي استحكام باند ريز برشي يك نوع باندينگ نانوفيلر، با و بدون قرار گرفتن در چرخه‌هاي حرارتي توسط دستگاه ابداعي
پديد آورندگان :
جابري انصاري ، زهرا 1334 نويسنده پزشكي , , خليلي، حميد نويسنده , , كشاورز ترك، محمدعلي نويسنده دندانپزشك , , اميري سياوشاني، مانوشا نويسنده دستيار تخصصي گروه آموزشي دندانپزشكي ترميمي دانشكده دندانپزشكي دانشگاه علوم پزشكي شهيدبهشتي، تهران، ايران ,
اطلاعات موجودي :
فصلنامه سال 1392 شماره 88
رتبه نشريه :
علمي پژوهشي
تعداد صفحه :
6
از صفحه :
222
تا صفحه :
227
كليدواژه :
thermal cycles , Bonding , nanofiller , Micro-shear bond strength
چكيده لاتين :
Abstract Background and Aim: Estimation of the survival of dental materials is especially important when manufacturing new materials. Thermocycling can greatly help in this respect. The purpose of this study was to evaluate the microshear bond strength of a nanofiller bonding agent with and without thermocycling in a newly invented device. Materials and Methods: In this experimental study, human third molars were sec-tioned into 1.5 mm slices after extraction and disinfection. Clearfil Tri-S nanofiller bond was applied to the dentin part of sections according to the manufacturer’s in-structions. Clearfil AP-X composite resin was placed over the dentin using tubes with 0.75 mm internal diameter and one mm height and light cured. Specimens were randomly divided into three groups and subjected to thermocycling in a newly invented device for zero, 3000 and 5000 cycles between 5±2°C and 55±2°C. Micro-shear bond strength was measured by microtensile tester with a cross-head speed of 0.5 mm/min. Obtained data were analyzed using one-way ANOVA. Tukey’s test was used for multiple comparisons with a 95% confidence interval. Results: The mean micro-shear bond strength after zero, 3000 and 5000 thermal cycles was found to be 19.27±4.56, 17.00±6.52 and 11.58±4.64 MPa, respectively. The reduction in bond strength between zero and 3000 thermal cycles was not statis-tically significant (P=0.3) but this reduction between zero and 5000, as well as 3000 and 5000 cycles was statistically significant (P < 0.002 and P < 0.03, respectively). Conclusion: Increase in number of thermal cycles for more than 3000 reduces the micro-shear bond strength of Tri-S bonding agent. Key Words: Micro-shear bond strength , bonding , thermal cycles , nanofiller
سال انتشار :
1392
عنوان نشريه :
دندانپزشكي - جامعه اسلامي داندانپزشكان
عنوان نشريه :
دندانپزشكي - جامعه اسلامي داندانپزشكان
اطلاعات موجودي :
فصلنامه با شماره پیاپی 88 سال 1392
كلمات كليدي :
#تست#آزمون###امتحان
لينک به اين مدرک :
بازگشت