شماره ركورد :
912027
عنوان مقاله :
كاهش دماي استخوان در زمان دريل‌كاري با استفاده از الكل: گزارش كوتاه
عنوان فرعي :
Bone temperature reduction during drilling via alcohol: brief report
پديد آورندگان :
عفت‌پرور، محمدرضا نويسنده Biomedical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran. Effatparvar, Mohammadreza , جمشیدی، نیما نويسنده Biomedical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran. Jamshidi, Nima , كریمیان، علی‌رضا نويسنده Biomedical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran. Karimian, Alireza
اطلاعات موجودي :
ماهنامه سال 1395 شماره 0
رتبه نشريه :
علمي پژوهشي
تعداد صفحه :
4
از صفحه :
597
تا صفحه :
600
كليدواژه :
نكروز استخوان , Kirschner wires , alcohol , الكل , واير كريشنر , bone necrosis
چكيده فارسي :
زمینه و هدف: كاهش دمای استخوان در محل دریل‌كاری با روش‌های مختلف خنك‌كننده ضروری است. مطالعه حاضر در جهت بررسی تاثیر الكل به‌عنوان خنك‌كننده در جلوگیری از نكروز حرارتی انجام گرفت. روش بررسی: استخوان فمور گاو به‌عنوان نمونه مورد بررسی انتخاب شد و معیارهای ورود شامل، استخوان فمور، كورتیكال و عدم وجود پریوست بود. دریل كاری با دو نوع كاوایر تروكار و دایاموند و در سه سرعت و سه پیشروی انجام شد. این مطالعه در اسفند ماه سال 94 در دانشگاه اصفهان صورت گرفت. یافته‌ها: در زمان استفاده از وایر تروكار و دایاموند در شرایط حضور الكل ریسك نكروز در استخوان به‌ترتیب به‌میزان نزدیك به 44/44 و 66/66% كاهش یافت. نتیجه‌گیری: با توجه به نتایج ثبت شده، استفاده از الكل به‌عنوان خنك‌كننده می‌تواند تاثیر به‌سزایی در كاهش دمای نهایی داشته باشد. در این روش استفاده از الكل در قالب سایش گاز آغشته به الكل بر روی كاوایر در زمان كارگزاری بود.
چكيده لاتين :
Background: Cooling is one of the main processes in bone temperature decrement, while drilling. this experiment was conducted for examination of alcohol effect as cooler in prevention of thermal necrosis. Methods: Bovine femur bone was considered as specimen and inclusions criteria for this study were: femur bone, cortical area and without bone periosteum. Drilling process was conducted by two types of k-wire- Trocar and Diamond, three speeds and three feed rates and in the time of march, 2016 in the place of university of Isfahan, Iran. Two type of thermometer- K-thermocouple and infrared thermometer- were used for temperature measurement, and all data were logged by data logger. Drilling processes were conducted by milling machine with ability of table movement for feed rate parameter. Method of alcohol usage in cooling was in form of conducting alcoholic gauze with k-wire while rotating. Results: Totally in the cases of trocar and diamond wires, while were cooled by alcohol, the risk of bone necrosis decreased about 44.44% and 66.66%. All temperature data were logged by changing parameters. maximum temperature, 94.5 °C, belonged to trocar wire in a non-cooling condition and after usage of cooler it decreased to 75 °C.  In the usage of diamond wires, the maximum temperature was recorded 71 °C and the temperature while using alcohol was 51 °C. Diamond wire had better result in both conditions of cooling and no cooling, and this is related to geometric differences between two types of wires. Conclusion: Due to obtained data from examination, utilization alcohol can have an important influence on final bone temperature decreasing. The way of using alcohol was in the style of attrition soaked gauze onto wire while insertion.