عنوان مقاله :
حذف باكتريهاي اشرشياكلي و استافيلوكوكوس اورئوس از آب آلوده
بهروش الكتروليز با الكترودهاي آلومينيم- آهن
عنوان فرعي :
Removal of E. coli and S. aureus from polluted water using electrolysis method with Al-Fe electrodes
پديد آورنده :
غلامی میترا
پديد آورندگان :
نظري شهرام نويسنده دانشگاه ايوانكي, , ياري احمد رضا نويسنده , محسنی سید محسن نويسنده Department of Environmental Health Engineering, School of Public Health, Shahid Beheshti University of Medical Sciences, Tehran, Iran. Mohseni Seyed Mohsen , علیزاده متبوع سودابه نويسنده Department of Environmental Health Engineering, School of Public Health, Ardabil University of Medical Sciences, Ardabil, Iran. Alizadeh Matboo Soudabeh
سازمان :
Department of Environmental Health Engineering, Iran University of Medical Sciences, Tehran, Iran.
اطلاعات موجودي :
ماهنامه سال 1396 شماره 0
كليدواژه :
گندزدايي , الكتروليز , اشرشياكلي , Drinking water , Escherichia coli , electrolysis , آب آشاميدني , Staphylococcus aureus , استافيلوكوكوس اورئوس , Disinfection
چكيده فارسي :
زمینه و هدف: گندزدایی آب به روش الكترولیز در سالهای اخیر رو به گسترش است. هدف از انجام این پژوهش بررسی حذف باكتریهای اشرشیاكلی و استافیلوكوكوس اورئوس به روش الكترولیز با الكترود آلومینیم- آهن به حالت تك قطبی موازی از آب آشامیدنی بود.
روش بررسی: مطالعه بهصورت تجربی در خرداد ماه ۱۳۹۵ در آزمایشگاه میكروبیولوژی دانشگاه علوم پزشكی ایران انجام گردید. نمونههای آب آلوده با افزودن ۱۰۳، ۱۰۴ و ۱۰۵ عدد باكتری اشرشیاكلی و استافیلوكوكوس اورئوس در میلیلیتر آب آشامیدنی تهیه گردید. متغیرهای مستقل فرآیند شامل سویههای باكتریایی اشرشیاكلی و استافیلوكوكوس اورئوس با غلظتهای مختلف باكتریایی ۱۰۳، ۱۰۴ و ۱۰۵ عدد در میلیلیتر (pH اولیه (۷، ۸ و ۹)، زمان واكنش (۵، ۱۰، ۱۵، ۲۰ و ۲۵ دقیقه)، فاصله بین الكترودها (۱، ۲ و cm ۳) و چگالی جریان (۰/۸۳، ۱/۶۷ و mA/cm2 ۳/۳) جهت تعیین شرایط بهینه بررسی شد.
یافتهها: نتایج نشان میدهد كه در شرایط بهینه با افزایش pH از هفت به ۹ راندمان حذف سویههای باكتریایی اشرشیاكلی بهطور معناداری از ۹۸ به ۷۳% و استافیلوكوكوس اورئوس از ۹۹/۱ به ۷۶% كاهش پیدا میكند. در غلظت اولیهCFU/ml ۱۰۴ شرایط بهینه برای pH، چگالی جریان، زمان واكنش و فاصله بین الكترودها بهترتیب برابر ۷، mA/cm2 ۱/۶۷، ۲۰ دقیقه و cm ۲ بهدست آمد. افزایش چگالی جریان و زمان واكنش باعث كاهش معناداری در هر دو سویه باكتریها شد. میزان انرژی برق مصرفی در شرایط بهینه 3KWh/m ۰/۵۱۲۸ محاسبه شد. آزمون آماری صورت گرفته نشان از معناداری (۰/۰۱P<) رابطه غلظتهای اولیه سویههای باكتریایی و راندمان فرایند میباشد.
نتیجهگیری: بر اساس نتایج راندمان حذف سویههای باكتریایی اشرشیاكلی و استافیلوكوكوس اورئوس بیشتر از ۹۸% بهدست آمد.
چكيده لاتين :
Background: Electrolysis is an electrochemical method for the treatment of water. recently water disinfection by electrochemical methods has been increasingly carried out. The aim of this applied research was to investigate the removal of Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) bacteria from drinking water by using electrolysis method with Al-Fe electrodes parallel with the monopole mode.
Methods: An experimental study was conducted in the laboratory of microbiology, Iran University of Medical Science in May 2017. In this study, the contaminated water samples were prepared through adding 103, 104 and 105 E. coli and S. aureus bacteria per 1 milliliters (mL) of drinking water. Independent variables Included: different concentrations of E.coli and S. aureus bacteria (103, 104 and 105 CFU/ml), reaction time (5, 10, 15, 20 and 25 min), initial pH (7, 8 and 9), electrode gap (1, 2 and 3 cm), current density (0.83, 1.67 and 3.3 mA/cm2) to determine the optimum conditions were investigated. One-way ANOVA was used to analyze the results.
Results: The results show that in the optimum conditions with increasing the pH from 7 to 9 removal efficiency of bacterial strains of E. coli and S. aureus were decreased significantly from 98 to 73% and 99.1 to 76%, respectively. In initial concentration of 104 CFU/ml, optimum conditions were obtained for current density, reaction time and electrodes gap, 1.67 mA/cm2, 20 min and 2 cm, respectively. With increasing current density and reaction time in both strains of bacteria, were decreased significantly. The electrodes gap do not have much impact on the efficiency of the process. The amount of electrical energy consumed in optimal conditions was calculated 0.5128 kilowatt-hour (kWh/h). Statistical analysis shows that exist significant relationship (P<0.01) between initial concentrations of bacterial strains and efficiency of the process.
Conclusion: According to the results, E. coli and S. aureus, removal efficiency were obtained more than 98%, therefore electrolysis process can be used in the removal of pathogenic bacteria from drinking water.
عنوان نشريه :
مجله دانشكده پزشكي دانشگاه علوم پزشكي تهران
عنوان نشريه :
مجله دانشكده پزشكي دانشگاه علوم پزشكي تهران
اطلاعات موجودي :
ماهنامه با شماره پیاپی 0 سال 1396