Title of article :
Effect of blood sample handling post-collection on Erysipelothrix rhusiopathiae antibody titres
Author/Authors :
Neumann، نويسنده , , Eric J. and Bonistalli، نويسنده , , Kathryn N.، نويسنده ,
Issue Information :
فصلنامه با شماره پیاپی سال 2009
Abstract :
A study was conducted to determine the effect of blood sample mishandling on the performance of an enzyme-linked immunosorbent assay for the detection of antibodies against Erysipelothrix rhusiopathiae. Eleven sample maltreatments (storage at −10 °C, storage at 4 °C, heat treatment of clotted blood, haemolysis, repetitive freeze–thaw cycling, and substitution of plasma in place of serum) were simulated in a laboratory environment and then run concurrently against a gold standard sample (storage at −80 °C).
shandling treatment groups that simulated high levels of haemolysis had significantly lower optical density (OD) readings when compared to the gold standard. However, the magnitude of the effects was relatively small and only samples with OD values close to the cut-off changed state from positive to negative. Heat treatment had a minor, but non-significant, effect on OD values. Findings from this study suggested that immunoglobulin G antibody was stable in the face of most common sample mishandling events.
Keywords :
Enzyme-linked immunosorbent assay , Blood , serum , Agreement , Storage
Journal title :
The Veterinary Journal
Journal title :
The Veterinary Journal