Title of article :
Two-phase pressure drop, boiling heat transfer, and critical heat flux to water in a small-diameter horizontal tube
Author/Authors :
Yu، نويسنده , , W. and France، نويسنده , , D.M. and Wambsganss، نويسنده , , M.W. and Hull، نويسنده , , J.R.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Abstract :
Two-phase pressure drop, boiling heat transfer, and critical heat flux to water were studied in a small horizontal tube of 2.98-mm inside diameter and 0.91-m heated length. Experiments were performed at a system pressure of 200 kPa, mass fluxes of 50–200 kg/m2s, and inlet temperatures from ambient to 80 °C. Experimental results and comparisons with state-of-the-art predictive correlations are presented. Modifications were made to the Chisholm two-phase multiplier correlation and to the Argonne National Laboratory small-channel boiling heat transfer correlation to better predict the experimental data of the present study.
Keywords :
Pressure drop , Critical heat flux , Small channel , Horizontal flow , Boiling heat transfer
Journal title :
International Journal of Multiphase Flow
Journal title :
International Journal of Multiphase Flow