Title of article :
Clinical determination of 17-hydroxyprogesterone in serum by LC–MS/MS: Comparison to Coat-A-Count™ RIA method
Author/Authors :
Etter، نويسنده , , Michele L. and Eichhorst، نويسنده , , Jeff and Lehotay، نويسنده , , Denis C.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
17α-Hydroxyprogesterone is a metabolic precursor of cortisol; elevated levels of 17α-hydroxyprogesterone are indicative of congenital adrenal hyperplasia. Traditional determination by immunoassay is plagued by poor antibody specificity, resulting in significant interferences. This study explores an LC–MS/MS method for the quantitation of 17OHP in serum. Deuterated 17α-hydroxyprogesterone was added as internal standard, followed by solid-phase extraction, HPLC separation with a C16-amide reverse-phase column with run time of 7 min, and quantification by MS/MS (positive electrospray ionisation) in the selected reaction monitoring mode (SRM). Transitions monitored were 331 > 109 for the analyte and 339 > 113 for the deuterated internal standard. Intra-assay precision (%R.S.D.) was 7.4% at 7 nmol/L, inter-assay precision (%R.S.D.) at 2, 7 and 27 nmol/L was 15.4, 10.0 and 7.9% and accuracy at 0.9 nmol/L was 100%. The method was linear from 0.156 to 80 nmol/L. Lower limit of quantitation was 0.2 nmol/L, providing meaningful data for patients within normal range as well as those with elevated levels.
Keywords :
LC–MS/MS , CAH , 17-Hydroxy progesterone , SPE , RIA , Congenital adrenal hyperplasia
Journal title :
Journal of Chromatography B
Journal title :
Journal of Chromatography B