Title of article :
Optimization of air staging in a 1 MW tangentially fired pulverized coal furnace
Author/Authors :
Li، نويسنده , , Sen and Xu، نويسنده , , Tongmo and Hui، نويسنده , , Shien and Zhou، نويسنده , , Qulan and Tan، نويسنده , , Houzhang، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
8
From page :
99
To page :
106
Abstract :
This paper deals with an experimental study of air staging in a 1 MW (heat input power) tangentially fired pulverized coal furnace. The influences of several variables associated with air staging on NOx reduction efficiency and unburned carbon in fly ash were investigated, and these variables included the air stoichiometric ratio of primary combustion zone (SR1), the locations of over-fire air nozzles along furnace height, and the ratio of coal concentration of the fuel-rich stream to that of the fuel-lean one (RRL) in primary air nozzle. The experimental results indicate that SR1 and RRL have optimum values for NOx reduction, and the two optimum values are 0.85 and 3:1, respectively. NOx reduction efficiency monotonically increases with the increase of OFA nozzle location along furnace height. On the optimized operating conditions of air staging, NOx reduction efficiency can attain 47%. Although air staging can effectively reduce NOx emission, the increase of unburned carbon in fly ash should be noticed.
Keywords :
Air staging , NOx reduction , unburned carbon
Journal title :
Fuel Processing Technology
Serial Year :
2009
Journal title :
Fuel Processing Technology
Record number :
1508304
Link To Document :
بازگشت