Title of article :
UV dosimeters based on neotetrazolium chloride
Author/Authors :
Mills، نويسنده , , Andrew and Grosshans، نويسنده , , Pauline and McFarlane، نويسنده , , Michael، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
6
From page :
136
To page :
141
Abstract :
A novel UV dosimeter is described comprising a tetrazolium dye, neotetrazolium chloride (NTC), dissolved in a film of polymer, polyvinyl alcohol (PVA). The dosimeter is pale yellow/colourless in the absence of UV light, and turns red upon exposure to UV light. The spectral characteristics of a typical UV dosimeter film and the mechanism through which the colour change occurs are detailed. The NTC UV dosimeter films exhibit a response to UV light that is related to the intensity and duration of UV exposure, the level of dye present in the films and the thickness of the films themselves. The response of the dosimeter is temperature independent over the range 20–40 °C and, like most UV dosimeters, exhibits a cosine-like response dependence upon irradiance angle. The introduction of a layer of a UV-screening compound which slows the rate at which the dosimeter responds to UVR enables the dosimeter response to be tailored to different UV doses. The possible use of these novel dosimeters to measure solar UV exposure dose is discussed.
Keywords :
UV dosimeter , UV index , MED , Tetrazolium
Journal title :
Journal of Photochemistry and Photobiology:A:Chemistry
Serial Year :
2009
Journal title :
Journal of Photochemistry and Photobiology:A:Chemistry
Record number :
1616764
Link To Document :
بازگشت