Title of article :
Cell failure mechanisms in PEM water electrolyzers
Author/Authors :
Millet، نويسنده , , P. and Ranjbari، نويسنده , , A. and de Guglielmo، نويسنده , , F. and Grigoriev، نويسنده , , S.A. and Auprêtre، نويسنده , , F.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
10
From page :
17478
To page :
17487
Abstract :
PEM water electrolysis offers an efficient and flexible way to produce “green-hydrogen” from renewable (intermittent) energy sources. Most research papers published in the open literature on the subject are addressing performances issues and to date, very few information is available concerning the mechanisms of performance degradation and the associated consequences. Results reported in this communication have been used to analyze the failure mechanisms of PEM water electrolysis cells which can ultimately lead to the destruction of the electrolyzer. A two-step process involving firstly the local perforation of the solid polymer electrolyte followed secondly by the catalytic recombination of hydrogen and oxygen stored in the electrolysis compartments has been evidenced. The conditions leading to the onset of such mechanism are discussed and some preventive measures are proposed to avoid accidents.
Keywords :
Water electrolysis , Safety , Hydrogen , PEM