Title of article :
The thermal-hydraulic calculation and analysis of the medium temperature platen superheater in a 300 MWe CFB boiler
Author/Authors :
Wu، نويسنده , , Haibo and Zhang، نويسنده , , Man Ji Sun، نويسنده , , Yunkai and Lu، نويسنده , , Qinggang، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
9
From page :
590
To page :
598
Abstract :
The characteristics of outlet steam temperature and the metal temperature of the medium temperature platen superheater at different boiler loads was obtained in a 300 MWCFB boiler, the result shows that the imbalance rate of tube mass flux is determined by the structure of header and tube. Generally Z type arrangement is one of the reasonable types arrangement.
Keywords :
300 MWe CFB boiler , Medium temperature platen superheater , Hydrodynamics , Metal temperature