Title of article
Influence of fluoride, hydrogen peroxide and lactic acid on the corrosion resistance of commercially pure titanium
Author/Authors
Mabilleau، نويسنده , , G. Le bourdon، نويسنده , , S. and Joly-Guillou، نويسنده , , M.L. and Filmon، نويسنده , , R. and Baslé، نويسنده , , M.F. and Chappard، نويسنده , , D.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
9
From page
121
To page
129
Abstract
Titanium is widely used in dental implantology and orthopaedics due to its excellent corrosion resistance and mechanical properties. However, it has been reported that Ti is sensitive to F−, H2O2 and lactic acid. Atomic force microscopy (AFM) and scanning electron microscopy (SEM) were used to investigate the corrosion resistance of CP-Ti disks after 9 days immersion in different test solutions, based on artificial saliva containing F− (0.5% and 2.5%), H2O2 (0.1% and 10%) and/or lactic acid. Because activated macrophages and bacteria can also release locally some of these oxidative compounds, we investigated the role of these cells when plated onto titanium disks. The surface roughness (Ra) was highly increased when titanium disks were immersed in artificial saliva containing F−, H2O2 and lactic acid. After 21 days of cell culture, Ra was significantly increased on disks incubated with activated-J774.2 cells or Streptococcus mitis. AFM appeared to be more sensitive than SEM in evaluating the corrosion of the titanium. Chemical species, either environmental or those released by macrophages and bacteria, can provoke a marked attack of the titanium surface.
Keywords
Titanium , Hydrogen peroxide , Corrosion , fluoride , lactic acid
Journal title
Acta Biomaterialia
Serial Year
2006
Journal title
Acta Biomaterialia
Record number
1751960
Link To Document