Title of article :
Predicting Survival in Patients Receiving Continuous Flow Left Ventricular Assist Devices: The HeartMate II Risk Score
Author/Authors :
Cowger، نويسنده , , Jennifer and Sundareswaran، نويسنده , , Kartik and Rogers، نويسنده , , Joseph G. and Park، نويسنده , , Soon J. and Pagani، نويسنده , , Francis D. and Bhat، نويسنده , , Geetha and Jaski، نويسنده , , Brian and Farrar، نويسنده , , David J. and Slaughter، نويسنده , , Mark S.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
9
From page :
313
To page :
321
Abstract :
Objectives m of this study was to derive and validate a model to predict survival in candidates for HeartMate II (HMII) (Thoratec, Pleasanton, California) left ventricular assist device (LVAD) support. ound ortality risk prediction is important for candidate selection and communicating expectations to patients and clinicians. With the evolution of LVAD support, prior risk prediction models have become less valid. s ts enrolled into the HMII bridge to transplantation and destination therapy trials (N = 1,122) were randomly divided into derivation (DC) (n = 583) and validation cohorts (VC) (n = 539). Pre-operative candidate predictors of 90-day mortality were examined in the DC with logistic regression, from which the HMII Risk Score (HMRS) was derived. The HMRS was then applied to the VC. s were 149 (13%) deaths within 90 days. In the DC, mortality (n = 80) was higher in older patients (odds ratio [OR]: 1.3, 95% confidence interval [CI]: 1.1 to 1.7 per 10 years), those with greater hypoalbuminemia (OR: 0.49, 95% CI: 0.31 to 0.76 per mg/dl of albumin), renal dysfunction (OR: 2.1, 95% CI: 1.4 to 3.2 per mg/dl creatinine), coagulopathy (OR: 3.1, 95% CI: 1.7 to 5.8 per international normalized ratio unit), and in those receiving LVAD support at less experienced centers (OR: 2.2, 95% CI: 1.2 to 4.4 for <15 trial patients). Mortality in the DC low, medium, and high HMRS groups was 4%, 16%, and 29%, respectively (p < 0.001). In the VC, corresponding mortality was 8%, 11%, and 25%, respectively (p < 0.001). HMRS discrimination was good (area under the receiver-operating characteristic curve: 0.71, 95% CI: 0.66 to 0.75). sions RS might be useful for mortality risk stratification in HMII candidates and may serve as an additional tool in the patient selection process.
Keywords :
left ventricular assist device , mortality , Risk , Heart Failure
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2013
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
1755517
Link To Document :
بازگشت