David، نويسنده , , C. and Panigrahi، نويسنده , , B.K. and Amarendra، نويسنده , , G. and Abhaya، نويسنده , , S. and Balaji، نويسنده , , S. and Balamurugan، نويسنده , , A.K. and Nair، نويسنده , , K.G.M. and Viswanathan، نويسنده , , B. Hema Sundar Raju، نويسنده , , C.S. and Raj، نويسنده , , Baldev، نويسنده ,
Abstract :
The void swelling behaviour of (15Ni–14Cr) Ti-modified steels simulated by heavy ion irradiation, has been investigated using step height measurements and positron annihilation spectroscopy. 18% cold-worked samples were pre-implanted with helium at 170 keV and 275 keV energies so as to create a uniform helium concentration of 100 appm around the 588 nm depth region. This was followed by a 2.5 MeV Ni ion irradiation to create a peak damage of ~ 84 dpa (displacement per atom) at various irradiation temperatures between 700 and 970 K. The gross swelling which has occurred throughout the ion range is determined by step height measurements. Defect-sensitive positron annihilation lineshape S-parameter measurements show clear changes consequently to void formation as a function of sample depth. From the variation of the average S-parameter as a function of irradiation temperature, the peak swelling temperature has been deduced. The changes observed in step height measurements are compared with positron annihilation measurements and the results are discussed.