Title of article :
Electrochemical stability of TiO2 nanotubes with different diameters in artificial saliva
Author/Authors :
Liu، نويسنده , , Chenglong and Wang، نويسنده , , Yueji and Wang، نويسنده , , Meng and Huang، نويسنده , , Weijiu and Chu، نويسنده , , Paul K.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Abstract :
Recently, titanium and titanium alloys with nanotube layers by anodizing process have gained great interests as surgical implant materials. In this present paper, their electrochemical stability of self-organized TiO2 nanotubue layers prepared by anodization of pure Ti in 0.5 wt.% hydrofluoric acid has been investigated in simulated biological environment by use of open-circuit potential (OCP), electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization tests. The electrochemical testing results indicate that the nanotubular Ti with the diameter of TiO2 nanotube lower than 86 nm shows a better corrosion resistance in artificial saliva than that of the mechanically polished Ti. Moreover, the electrochemical stability of Ti nanotubes 22 to 59 nm in diameter is improved but that of Ti nanotubes larger than 86 nm decreases. Besides, the corrosion attack of the nanotubular Ti is shown by the collapse of TiO2 nanotubue layer. The results suggest that the electrochemical corrosion behavior of nanotubular Ti in artificial saliva is related to the diameter of the nanotubes and thickness of the barrier layer.
Keywords :
biomaterial , Anodizing , Nanotubular Ti , Corrosion , Electrochemical stability
Journal title :
Surface and Coatings Technology
Journal title :
Surface and Coatings Technology