• Title of article

    A convenient way to find an electrical insulation break of MA cores in J-PARC synchrotrons

  • Author/Authors

    Nomura، نويسنده , , M. and Schnase، نويسنده , , A. and Shimada، نويسنده , , T. and Tamura، نويسنده , , F. and Yamamoto، نويسنده , , James M. and Hara، نويسنده , , K. and Hasegawa، نويسنده , , K. and Ohmori، نويسنده , , C. and Toda، نويسنده , , M. and Yoshii، نويسنده , , M.، نويسنده ,

  • Pages
    5
  • From page
    83
  • To page
    87
  • Abstract
    We employ Magnetic Alloy core loaded RF cavities for the Japan Proton Accelerator Research Complex synchrotrons to achieve a high accelerating voltage. To improve the electrical insulation of MA cores, we conceptualized a convenient way to find an electrical insulation break by measuring the DC resistance in the radial directions of MA cores. We call it the radial resistance method. This radial resistance method gives information of the radial location and degree of the electrical insulation breaks of MA cores. We checked the validity of the radial resistance method by comparing with a high power test result. The areas where the radial resistance method indicated the electrical insulation breaks corresponded with the areas that were damaged due to the electrical insulation breaks during the high power test. We modified the core manufacturing process by evaluating the electrical insulation of MA cores from the radial resistance data, and thus we could improve the electrical insulation of MA cores.
  • Keywords
    RF cavity , Proton synchrotron , Magnetic Alloy core
  • Journal title
    Astroparticle Physics
  • Record number

    2018993