Liu، نويسنده , , J. and Cai، نويسنده , , B. and Carr، نويسنده , , R. and Dwyer، نويسنده , , D.A. and Gu، نويسنده , , W.Q. and Li، نويسنده , , G.S. and Qian، نويسنده , , X. and McKeown، نويسنده , , R.D. and Tsang، نويسنده , , R.H.M. and Wang، نويسنده , , W. and Wu، نويسنده , , F.F. and Zhang، نويسنده , , C.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
19
From page :
19
To page :
37
Abstract :
We describe the automated calibration system for the antineutrino detectors in the Daya Bay Neutrino Experiment. This system consists of 24 identical units instrumented on 8 identical 20-ton liquid scintillator detectors. Each unit is a fully automated robotic system capable of deploying an LED and various radioactive sources into the detector along given vertical axes. Selected results from performance studies of the calibration system are reported.