Title of article :
Use of activated charcoal for the purification of neon in the CLEAN experiment
Author/Authors :
Harrison، نويسنده , , M.K. and Lippincott، نويسنده , , W.H. and McKinsey، نويسنده , , D.N. and Nikkel، نويسنده , , J.A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
5
From page :
556
To page :
560
Abstract :
Passage of neon gas through activated charcoal is planned to be the primary method of removing impurities from the liquid neon scintillator in the CLEAN experiment. In order to quantify this technique, the breakout curves for hydrogen, nitrogen, argon and krypton impurities in neon-saturated activated charcoal were measured. Adsorption coefficients and the number of theoretical stages were measured for hydrogen in the temperature range between 300 and 80 K, nitrogen between 300 and 200 K, and argon between 300 and 190 K. The adsorption coefficient for krypton was measured at 300 K.
Keywords :
CLEAN experiment , Cryogenic traps , Activated charcoal , Purification of argon , krypton , mass spectrometry , Nitrogen and hydrogen in neon
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2007
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2202501
Link To Document :
بازگشت