Title of article :
Overview of ECE diagnostics on LHD
Author/Authors :
Nagayama، نويسنده , , Y and Inagaki، نويسنده , , S and Sasao، نويسنده , , H and de Vries، نويسنده , , P and Ito، نويسنده , , Y and Kawahata، نويسنده , , K and Narihara، نويسنده , , K and Yamada، نويسنده , , I، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
11
From page :
201
To page :
211
Abstract :
An electron cyclotron emission (ECE) diagnostic system has been installed on the large helical device (LHD). In LHD, the magnetic field profile has a peak near the plasma center, so the electron temperature profile of both sides can be continuously measured by the ECE system using two antennas. The ECE spectrometers are as follows, two heterodyne radiometers with the local frequency of 70 and 132 GHz, respectively, a grating polychromator and a Michelson spectrometer. The measurements are processed by the distributed data acquisition system. The angle of the magnetic field from the toroidal direction varies from −30 to +30° in LHD. It is found that the polarization of ECE follows the angle of the magnetic field when the electron density is high enough. The effect of the polarization is considered when the temperature calibration is performed. ECE is useful to distinguish small perturbations in the electron temperature profile, for example, to effects of a local island diverter.
Keywords :
Large helical device , Electron cyclotron emission , Magnetic field
Journal title :
Fusion Engineering and Design
Serial Year :
2001
Journal title :
Fusion Engineering and Design
Record number :
2351040
Link To Document :
بازگشت