Title of article :
Manufacture of first wall mock-ups with calibrated defects for fabrication control methods: Development of UT detectable defects
Author/Authors :
Bobin، نويسنده , , I. and Boireau، نويسنده , , B. and Cottin، نويسنده , , A. and Burat، نويسنده , , O. and Lepers، نويسنده , , F. and Zacchia، نويسنده , , F. and Lorenzetto، نويسنده , , P.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Abstract :
A Research and Development program for the ITER Blanket-First Wall has been implemented in Europe to provide input data for the manufacture of the full-scale production components. In this frame, FW mock-ups have been fabricated according to ITER FW design requirements.
er to define acceptance criteria for non-destructive examination (NDE) for the series production, FW mock-ups (FWMU) representative of ITER FW are manufactured with calibrated defects to be validated by heat flux tests to assess the critical defect dimensions able to degrade fatigue performance and lifetime, when located at Be/CuCrZr joint corners and beryllium tile edges, and at the CuCrZr/CuCrZr and CuCrZr/316L SS joints.
er to create the defects of given dimensions, two techniques were studied: alumina and zirconia coating using a PVD technique in one hand; and on the another hand alumina and quartz thicker inserts.
per describes the different approaches used to manufacture test samples with calibrated defects, before applying on FW mock-ups, and related non-destructive examination (NDE) by ultrasonic examination (UT). High heat flux (HHF) testing is not part of this work.
Keywords :
First wall mock-ups (FWMU) , Hot isostatic pressing process (HIP) , Ultrasonic testing (UT) , Calibrated defects
Journal title :
Fusion Engineering and Design
Journal title :