Title of article :
Study of holdup and slip velocity in an L‑shaped pulsed sieve‑plate extraction column
Author/Authors :
Mohammadi, Elham Chemical Engineering Department - Tarbiat Modares University , Towfghi, Jafar Chemical Engineering Department - Tarbiat Modares University , Safdari, Jaber Materials and Nuclear Fuel Research School - Nuclear Science and Technology Research Institute , Mallah, Mohammad H Materials and Nuclear Fuel Research School - Nuclear Science and Technology Research Institute
Abstract :
High-end applications require a very tall vertical extraction column in some cases which deteriorates protection against
radiation and cannot be employed for indoor applications. On the other hand, horizontal extraction columns ofer higher
efciency and pretension, but lower maximum throughput. In order to address this issue, the L-shaped pulsed extraction
column is a new type of extractors which were recently introduced for such applications with area constraints. The objective
of this study is to evaluate the efects of operating parameters and physical properties on the variation of holdup and slip
velocity in this type of extractors for three liquid systems including toluene–water, butyl acetate–water and n butanol–water
without and under mass transfer condition. A comprehensive investigation on the determination of predictive ability of available correlations for the holdup and slip velocity in pulsed plate columns has been conducted. Finally, new correlations are
proposed for prediction of these parameters regarding operational conditions and physical properties.
Keywords :
L-shaped pulsed plate column , Slip velocity , Holdup , Pulsation intensity , Mass transfer
Journal title :
International Journal of Industrial Chemistry (IJIC)