Title of article :
A comparison between different parameters in F-wave studies
Author/Authors :
J. A. M. Nobrega، نويسنده , , G. M. Manzano، نويسنده , , P. T. Monteagudo، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Abstract :
Ulnar nerve F-waves were studied in 23 healthy volunteers and 27 diabetic patients. Latencies and chronodispersion were analyzed in each group. In the diabetic group all the parameters were normal in 14 patients (52%) and in 13 (48%) at least one parameter was altered. In these patients the most frequently altered parameter was the maximum latency (92%), followed by mean latency (85%), minimum latency (54%) and chronodispersion (54%). These findings suggest that maximum and mean latencies are better parameters to be analyzed in ulnar F-wave studies than minimum latency.
Keywords :
F-wave latency parameters , ulnar nerve , F-wave
Journal title :
Clinical Neurophysiology
Journal title :
Clinical Neurophysiology