Title of article
Subatmospheric pressure dressing for saphenous vein donor-site complications
Author/Authors
Steven E. Greer، نويسنده , , Eugene A. Grossi، نويسنده , , Douglas Chin، نويسنده , , Michael T. Longaker، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
3
From page
1038
To page
1040
Abstract
Newer endoscopic techniques have been successful at reducing saphenous vein donor-site wound complications, but not entirely eliminating them. Tissue necrosis with superimposed infection is typically treated with antibiotics and surgical debridement. Typically, primary reclosure is not possible and the open leg wound is allowed to slowly granulate with dressing changes until a skin graft can be performed. This report describes an alternative treatment using subatmospheric pressure dressing to promote granulation tissue and wound closure in saphenous vein donor-site wounds.
Journal title
The Annals of Thoracic Surgery
Serial Year
2001
Journal title
The Annals of Thoracic Surgery
Record number
604346
Link To Document