Title of article
Pilot-scale demonstration of phytofiltration for treatment of arsenic in New Mexico drinking water
Author/Authors
Mark P. Elless، نويسنده , , Charissa Y. Poynton، نويسنده , , Cari A. Willms، نويسنده , , Mike P. Doyle، نويسنده , , Alisa C. Lopez، نويسنده , , Dale A. Sokkary، نويسنده , , Bruce W. Ferguson، نويسنده , , Michael J. Blaylock، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
10
From page
3863
To page
3872
Abstract
Arsenic contamination of drinking water poses serious health risks to millions of people worldwide. To reduce such risks, the United States Environmental Protection Agency recently lowered the Maximum Contaminant Level for arsenic in drinking water from 50 to 10 μg L−1. The majority of water systems requiring compliance are small systems that serve less than 10,000 people. Current technologies used to clean arsenic-contaminated water have significant drawbacks, particularly for small treatment systems. In this pilot-scale demonstration, we investigated the use of arsenic-hyperaccumulating ferns to remove arsenic from drinking water using a continuous flow phytofiltration system. Over the course of a 3-month demonstration period, the system consistently produced water having an arsenic concentration less than the detection limit of 2 μg L−1, at flow rates as high as 1900 L day−1 for a total treated water volume of approximately 60,000 L. Our results demonstrate that phytofiltration provides the basis for a solar-powered hydroponic technique to enable small-scale cleanup of arsenic-contaminated drinking water.
Keywords
ferns , Phytoremediation , Hydroponics
Journal title
Water Research
Serial Year
2005
Journal title
Water Research
Record number
772610
Link To Document