Author/Authors :
D.، Meledin, نويسنده , , C.-Y.E.، Tong, نويسنده , , R.، Blundell, نويسنده , , G.، Goltsman, نويسنده , , N.، Kaurova, نويسنده , , K.، Smirnov, نويسنده , , B.، Voronov, نويسنده ,
Abstract :
In this paper, we present the results of IF bandwidth measurements on 3-4 nm thick NbN hot electron bolometer waveguide mixers, which have been fabricated on a 200-nm thick MgO buffer layer deposited on a crystalline quartz substrate. The 3dB IF bandwidth, measured at an LO frequency of 0.81 THz, is 3.7 GHz at the optimal bias point for low noise receiver operation. We have also made measurements of the IF dynamic impedance, which allow us to evaluate the intrinsic electron temperature relaxation time and self-heating parameters at different bias conditions.
Keywords :