چكيده لاتين :
The impulse oscillation system (lOS) measures respiratory impedance (Zrs) in terms of
resistance (Rrs) and reactance (Xrs) at multiples of 5 Hz. These measurements can be used
clinically to help diagnose and monitor respiratory disorders, independent of effort. There is,
as yet, no information on reference values for lOS in Iranian adolescents.
The predictive equation for resistance and impedance at 5 and 15 and 25 Hz, for the first
time , in 509 Iranian adolescent subjects (265 boys (aged 6-19 years) and 253 girls (aged 519
years) were determined. Gender-specific linear prediction equations were developed by
multiple regression anal ysis; with measuring (R5, R15, R25, X5, X15, X 25) as dependent
variables regressed against age (A) and height (H).
For both genders, age and height had negative effects on resistance, while age and height
had a positive effect on reactance. The prediction equations for R5 and X5 are as follows:
R5: -1.35x l 0-5 x age X2.823 - 0.001 x height x 1.022 + 0.547 for girls
X5: 1.78xl0-7x age x 1.08 + 0.002 height x4.150 - 0.539 , for girls
R5: -6.19 x l 0-7x age x 3.820 - 6.78E-005 Xheight x1.651 + 0.691 for boys
X5: 6.95 xl0-23 x age x 16.226 + 0.004height x 0.846- 0.430, for boys , respectively.
Our results therefore provide an original frame of reference for R5, R15, R25, X5, X15,
X25 in Iranian adolescents population, obtained from a standardized forced oscillation
technique.