پديد آورندگان :
Orewole M. O. نويسنده , Adekalu K. O. نويسنده , Makinde 0 . W. نويسنده , Shittu K. A. نويسنده
چكيده لاتين :
This study was undertaken to determine the changes in the physico-chemical properties of piped water
supplied in the state , between the treatment plant and points of use in lIe-Ife, Nigeria. Thirteen samples of
water were collected at different locations from treatment plant to the points of use and analyzed for the
follow ing selected parameters: alkalinity, total dissolved solids , total suspended solid, total solid,
potassium, sodium, calcium, magnesium , trace metals , sulphate and chloride. The results revealed that
between treatment plant at Ede and the point of use, there are changes in the considered physico-chemical
properties of the water supply.The most significant is the concentration oflead ion which was higher than
the recommended 0.0 Img/L by the world health organization and total alkalinity with a mean value of
(325.36±8 1.85) mg/L. The stud y concluded that the treatment proc ess needs to be reviewed to identify the
possible source of the ion and put nece ssary prev ention procedures.