چكيده لاتين :
The present study investigates the removal of pesticide by electrocoagulation process. A glass tank in 1.56 L
volume with four iron plate electrodes was used to perform the experiments. The electrodes connected to a
DC power supply (bipolar mode). The tank was filled with synthetic wastewater were which contained
dia zinon pesticide in concentration of 10, 50 and 100 mglL. The percent of diazinon remov al was measured
at pH= 3, 7 and 10 and in electric potential range of 20-40V by thin layer chromatography method. The
results indic ated that initi al concentration of dia zinon can affect efficiency removal and for higher
concentrations of diazinon, higher electrical potential or more reaction time is needed. The results showed
that for a given time , the removal efficiency increased significantly with increase of voltage. The highest
electrical potential (40V) produced the quickest treatment with >99% diazinon reduction occurring after 60
min . The final pH for iron electrodes was always higher than initial pH. Finally it can be concluded that
electrocoagulation process (using iron electrodes) is a reliable, efficient and cost-effective method for
removal of diazinon from aqueous environments, especially designed for pH=3 and voltage=40V.