كليدواژه :
Steel structures , Rigid connection , Khorjini Connection , Strain jump , Finite element
چكيده فارسي :
The purposeof this researchis tostudy the behaviorof conventional and retrofittedKhorjini connections.
Four plates, which were welded between the beams and column, added to the common details of the
connection. Two, common and retrofitted, connections were tested under monotonic loading. The tested
specimens were modeled by a finite element method, which verified with experimental results. Several
models with different size of the connection components were investigated using the verified FEM. The
results indicated that a main defect of the conventional connections is severe stiffness deterioration, while
Initial stiffness in the improved connections is more than four times the common detailed connections and
stiffness deterioration is not a case of concern. Moreover, a great proportion of beam moment in Khorjini
connections are carried to the column through beam flange to angle welds. Also, high stress concentration
occurs in the elastic phase of the critical weld in a short length of the weld, which yields to stain jump, when
the connection fails. However, in the retrofitted connections, added plates transfer a great amount of the
connection moment to the column, which yields to a considerable reduction in the maximum plastic strains
and von mises stresses in the critical weld. Consequently Retrofitted connections never fails, until beams
reach to their ultimate plastic moments