شماره ركورد كنفرانس :
4150
عنوان مقاله :
Finite element analysis of stress concentration in titanium dental implant with different thickness of hydroxyapatite coating
پديدآورندگان :
Bahmani Oskooee Mehdi m.bahmani@mee.uut.ac.ir Faculty of Materials Engineering Mining materials Engineering Department Urmia University of Technology Urmia, Iran ؛ Email:
تعداد صفحه :
4
كليدواژه :
Hydroxyapatite , dental implant , finite element , stress concentration
سال انتشار :
1396
عنوان كنفرانس :
اولين كنفرانس ملي مهندسي مواد، متالوژي و معدن
زبان مدرك :
انگليسي
چكيده فارسي :
Hydroxyapatite coating has been widely used on titanium dental implants in last decades. Stress concentration in the implant is an essential factor because it can cause the fracture of the implant, so we compare the effect of different thicknesses of hydroxyapatite layer on stress concentration in a titanium dental implant with finite element method software under axial chewing load of 200 N applied on top of the implant to see which one has the lowest stress concentration and is the best for dental applications. The results show that the best thickness of the hydroxyapatite layer is about 180 micrometer which minimizes the stress concentration in bone and maximizes the life of the implant.
كشور :
ايران
لينک به اين مدرک :
بازگشت