شماره ركورد كنفرانس :
5041
عنوان مقاله :
Introducing a New Experimental Method for Efficient Pinpointing of Minimum Miscible Pressure Parameter
Author/Authors :
A. A. Gharesheikhlou Petroleum Engineering Division - Research Institute of Petroleum Industry, Iran , S. Abbasi Petroleum Engineering Division - Research Institute of Petroleum Industry, Iran , S. Mohammadi Petroleum Engineering Division - Research Institute of Petroleum Industry, Iran , M. Elhambakhsh Petroleum Engineering Division - Research Institute of Petroleum Industry, Iran
كليدواژه :
Minimum Miscibility Pressure MMP , Immiscible Gas , Gas Injection , Slim tube
عنوان كنفرانس :
The 10th International Chemical Engineering Congress & Exhibition (IChEC 2018)
چكيده فارسي :
فاقد چكيده فارسي
چكيده لاتين :
Accurate experimental measuring of minimum miscible pressure parameter using slim tube
devices is always demanding but crucial and problematic test. By the passage of time, different
methods have been raised but there is no complete agreement on experimental pinpointing of this
important parameter. In other words, the results are always depends on final recovery factors
measured roughly in each pressure steps. This experimental research aims to introduce the
results of slim tube experimental set up commingled with continuous high pressure density meter
apparatus. Using this complementary device, effluent high pressure phase density was measured
continuously and density curves were interpreted precisely in each pressure step. The results
showed that coming close to minimum miscible pressure leads to appear a new transition zone in
density- pressure curve which is so called mixed density zone. During slim tube tests,
constructing of density profiles of effluent phase for some Iranian oil samples was considered.
Using these important density profiles one can determine precise estimation of minimum
miscible pressure so that true miscible or immiscible gas injection scenarios could be figure out.