شماره ركورد كنفرانس :
5048
عنوان مقاله :
Influence of Mass Transfer on Flooding Velocity in Pulsed Columns
Author/Authors :
Farideh ،Ghasempour Chemical Engineering Faculty - University of Tehran, Iran , Hossein ،Bahmanyar Chemical Engineering Faculty - University of Tehran, Iran
كليدواژه :
pulsed sieve perforated plate column , flooding , Mass Transfer , Direction of Mass Transfer
عنوان كنفرانس :
ششمين كنگره بين المللي مهندسي شيمي
چكيده لاتين :
Investigation of flooding velocity in different conditions has a great influence on designing the unit operations in
a more precise and accurate way, as well. In this paper, considering a pilot pulsed sieve plate extraction column,
the effects of the volumetric rates, pulsation rate, solute concentrations and mass transfer directions on the
flooding regions have been studied. We can conclude that by increasing of those effective operating parameters
the column floods rapidly as the same as without mass transfer systems. More over by increasing of solute
concentrations in dispersed phase transferred to continuous phase the drop coalescence circumstances are
improved and the flooding condition is occurred in higher flow rates. Otherwise mass transfer from continuous
to dispersed phase has reverse effects on maximum throughput.