Title :
The amount of linearization by barber-poles
Author_Institution :
Philips GmbH Forschungslaboratorium Hamburg, Hamburg, FRG.
fDate :
9/1/1984 12:00:00 AM
Abstract :
Barber-poles are well known means for linearization of the quadratic characteristic of the magnetoresistive effect. The paper reminds causes for incomplete linearization and introduces a model of a resistor with a linear and a quadratic term. The latter one is cancelled in the output of a bridge-type sensor, but is found in the resistance of the bridge. The quadratic part shows a marked dependence on geometry but there is also a contribution from the finite conductivity of the barber-poles. Measurement of the linear as well of the quadratic part of the magnetoresistive effect allows comparison of different barber-pole technologies.
Keywords :
Magnetoresistive transducers; Bridge circuits; Conductivity; Electrical resistance measurement; Geometry; Magnetic field measurement; Magnetic sensors; Magnetoresistance; Nonuniform electric fields; Resistors; Sensor phenomena and characterization;
Journal_Title :
Magnetics, IEEE Transactions on
DOI :
10.1109/TMAG.1984.1063191