DocumentCode :
1007782
Title :
Loss-minimising control scheme for induction motors
Author :
Lim, S. ; Nam, K.
Author_Institution :
Dept. of Electr. Eng., Pohang Univ. of Sci. & Technol., Kyoungbuk, South Korea
Volume :
151
Issue :
4
fYear :
2004
fDate :
7/7/2004 12:00:00 AM
Firstpage :
385
Lastpage :
397
Abstract :
Minimisation of the loss in the induction motor is directly related to the choice of the flux level. The higher the flux level, the larger the iron loss. But extreme minimisation causes a high copper loss. There is an optimal flux level that guarantees loss minimisation, and the loss-minimisation algorithm (LMA) was derived by many researchers. However, a technical problem in deriving the LMA lies in the loss model simplification. A loss model simplification is made with a voltage dependent source and loss resistance. The optimal LMA method extends to the field-weakening region where the voltage and current constraints constitute boundaries. A complete loss-minimising control algorithm is proposed and its validity is demonstrated by simulation and experimental results.
Keywords :
eddy current losses; induction motors; machine control; copper loss; induction motors; iron loss; loss resistance; loss-minimisation algorithm; loss-minimising control scheme; voltage dependent source;
fLanguage :
English
Journal_Title :
Electric Power Applications, IEE Proceedings -
Publisher :
iet
ISSN :
1350-2352
Type :
jour
DOI :
10.1049/ip-epa:20040384