• DocumentCode
    1008325
  • Title

    Use of a RF-SQUID in a quantum non demolition scheme

  • Author

    Bordoni, F. ; Carelli, P. ; Foglietti, V. ; Fuligni, F.

  • Author_Institution
    CNR Casella Postale, Frascati, Italy
  • Volume
    21
  • Issue
    2
  • fYear
    1985
  • fDate
    3/1/1985 12:00:00 AM
  • Firstpage
    421
  • Lastpage
    423
  • Abstract
    The sensitivity required for detecting gravitational waves seems higher than the limit imposed to a linear detector by quantum mechanics. To overcome this drawback, many groups are developing quantum non demolition (QND) schemes. Here we present a QND scheme based on the use of an RF-SQUID. The SQUID is used as a non linear element in order to obtain a combination of a three frequencies inverting and non inverting up-converter.
  • Keywords
    Gravity measurement; Josephson device measurement applications; Antenna measurements; Broadband amplifiers; Detectors; Motion detection; Motion measurement; Oscillators; Pollution measurement; Resonance; Temperature; Time measurement;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/TMAG.1985.1063659
  • Filename
    1063659