• DocumentCode
    1009212
  • Title

    Asynchronous inputs and flip-flop metastability in the CLAS trigger at CEBAF

  • Author

    Doughty, David C., Jr. ; Lemon, Stephan ; Bonneau, Peter

  • Author_Institution
    Christopher Newport Univ., Newport News, VA, USA
  • Volume
    40
  • Issue
    4
  • fYear
    1993
  • fDate
    8/1/1993 12:00:00 AM
  • Firstpage
    680
  • Lastpage
    684
  • Abstract
    The impact of flip-flop metastability on the pipelined trigger of the CEBAF Large Acceptance Spectrometer (CLAS) detector at the Continuous Electron Beam Accelerator Facility (CEBAF) is studied. It is found that the newest emitter-coupled logic (ECL) flip-flops (ECLinPS) are much faster than older families (10 H) at resolving the metastable condition. This will allow their use in systems with asynchronous inputs without an extra stage of synchronizing flip-flops
  • Keywords
    computerised instrumentation; flip-flops; nuclear electronics; trigger circuits; CEBAF; CEBAF Large Acceptance Spectrometer; Continuous Electron Beam Accelerator Facility; emitter-coupled logic; flip-flop metastability; metastable condition; pipelined trigger; Clocks; Data acquisition; Detectors; Electron beams; Energy resolution; Flip-flops; Linear accelerators; Metastasis; Pipelines; Spectroscopy;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.256640
  • Filename
    256640