DocumentCode :
1010635
Title :
Integration of Frequency Response Measurement Capabilities in Digital Controllers for DC–DC Converters
Author :
Shirazi, Mariko ; Morroni, Jeffrey ; Dolgov, Arseny ; Zane, Regan ; Maksimovic, Dragan
Author_Institution :
Dept. of Electr. & Comput. Eng., Univ. of Colorado, Boulder, CO
Volume :
23
Issue :
5
fYear :
2008
Firstpage :
2524
Lastpage :
2535
Abstract :
Recent work has shown the feasibility of integrating nonparametric frequency-domain system identification functionality into digital controllers for switched-mode pulse-width modulated (PWM) dc-dc power converters. The resulting discrete-time frequency response can be used for design, diagnostic, or self-tuning purposes. The success of these applications depends on the fidelity of the identified frequency responses and the degree to which the process is automated, as well as the costs, in terms of gate count, time duration of identification, and effect on output voltage, incurred to obtain these benefits. This paper demonstrates the feasibility of incorporating fully automated frequency response measurement capabilities in digital PWM controllers at relatively low additional cost. In particular, it is shown that relatively accurate and smooth frequency response data can be obtained using a Verilog-coded implementation with low tens of thousands of logic gates and about 10 kB of memory. The identification process can be accomplished in several hundred milliseconds and the output voltage can be kept within specified bounds during the entire process. Experimental results are provided for four different PWM dc-dc converters, including a synchronous buck with two different filter capacitors, a boost operating in continuous conduction mode (CCM), and a boost operating in discontinuous conduction mode (DCM).
Keywords :
DC-DC power convertors; PWM power convertors; digital control; frequency measurement; frequency response; hardware description languages; logic gates; power capacitors; power engineering computing; power filters; Verilog-coded implementation; automated frequency response measurement; continuous conduction mode; digital PWM controllers; discontinuous conduction mode; filter capacitors; frequency responses; logic gates; nonparametric frequency-domain system identification; switched-mode pulse-width modulated dc-dc power converters; synchronous buck; Costs; DC-DC power converters; Digital control; Digital-to-frequency converters; Frequency measurement; Frequency response; Pulse width modulation; Pulse width modulation converters; System identification; Voltage; Binary sequences; Hadamard transforms; correlation; dc–dc power conversion; digital control; frequency response; identification; pulse-width modulated (PWM) power converters; quantization; switched mode power supplies;
fLanguage :
English
Journal_Title :
Power Electronics, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8993
Type :
jour
DOI :
10.1109/TPEL.2008.2002066
Filename :
4689446
Link To Document :
بازگشت