DocumentCode
1011071
Title
Iron saturation effects in PM AC motors
Author
Chen, Ming-de ; Levi, Enrico ; Pelka, Markdov
Author_Institution
Institute of Electrical Engineering, Chinese Academy of Science, Beijing (Peking).
Volume
21
Issue
3
fYear
1985
fDate
5/1/1985 12:00:00 AM
Firstpage
1262
Lastpage
1265
Abstract
Iron saturation causes the lumped circuit parameters to vary with the point of operation. Experimental evidence shows that the field excitation voltage and the direct axis reactance are not affected significantly by the armature reaction. This can be attributed to the presence in the direct axis of the magnets whose thickness represents a large effective air gap. In the quadrature axis, instead, the contribution of the air gap to the reluctance is small. Therefore, the quadrature axis reactance depends strongly on both the quadrature and direct axis components of armature magnetomotive force. This suggests a simple, albeit approximate, approach for predicting the parameter variation with operating point. As a result, both the design and analysis of synchronous motors excited by permanent magnets (PM´s) are facilitated.
Keywords
Permanent magnet motors; AC motors; Armature; Bridge circuits; Iron; Magnetic analysis; Magnetic flux; Permanent magnet motors; Saturation magnetization; Synchronous motors; Voltage;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/TMAG.1985.1063889