• DocumentCode
    1024392
  • Title

    Saturation of the SIS direct detector and the SIS mixer

  • Author

    Feldman, M.J. ; D´Addario, L.R.

  • Author_Institution
    University of Virginia, Charlottesville, VA
  • Volume
    23
  • Issue
    2
  • fYear
    1987
  • fDate
    3/1/1987 12:00:00 AM
  • Firstpage
    1254
  • Lastpage
    1258
  • Abstract
    We review and discuss the theory of SIS direct detector saturation, and present experimental results which verify the theory, using N=2 and 4 SIS junctions in series. The measured responsivity is greater than the quantum limit e/Nhω. This is not understood, We derive an explicit formula for the saturation of the SIS mixer and compare this to the direct detector.
  • Keywords
    Millimeter-wave mixers; Millimeter-wave modulation/demodulation; Nonlinear detection; Superconductor insulator superconductor devices; Bolometers; Electrons; Extraterrestrial measurements; Frequency; Local oscillators; Observatories; Quantum mechanics; Radiation detectors; Submillimeter wave technology; Superconducting device noise;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/TMAG.1987.1065030
  • Filename
    1065030