• DocumentCode
    1028461
  • Title

    Voltage Endurance Tests of Insulating Materials Under Corona Conditions

  • Author

    Hewitt, G.W. ; Dakin, T.W.

  • Author_Institution
    Westinghouse Electric Corporation
  • Volume
    82
  • Issue
    69
  • fYear
    1963
  • Firstpage
    1033
  • Lastpage
    1039
  • Abstract
    A systematic study shows how the failure times of insulating materials exposed to corona discharges are influenced by various factors, including conductor edge surface discharge conditions, test frequency, void depth, humidity, temperature, material thickness, and average electric stress. Accelerated higher frequency tests permit testing at low-voltage stresses used continuously in applications. These yield results equivalent to 60-cps (cycles per second) tests, in cycles to failure, if both tests are run at low humidity with limited dielectric heating.
  • Keywords
    Conducting materials; Corona; Dielectrics and electrical insulation; Frequency; Humidity; Materials testing; Stress; Surface discharges; System testing; Voltage;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1963.291488
  • Filename
    4072902