DocumentCode :
1030140
Title :
Characteristics of epoxy-impregnated AC superconducting coils
Author :
Tanaka, Y. ; Matsumoto, K. ; Yamamoto, M. ; Tsukamoto, O. ; Ishigohka, T.
Author_Institution :
Furukawa Electric Co., Ltd., Yokohama, Japan
Volume :
23
Issue :
5
fYear :
1987
fDate :
9/1/1987 12:00:00 AM
Firstpage :
3554
Lastpage :
3556
Abstract :
Investigations of quench currents, stability and ac losses for several kinds of epoxy-impregnated ac superconducting coils are presented. As the first step, the temperature rise of epoxy-impregnated test coils wound with manganin heater wires were measured. From the results, it was demonstrated that the ac losses of 2-layer and 8-layer solenoidal superconducting coils and disc-type superconducting coils could be removed by the heat conduction through the epoxy without significant temperature rise, provided the thickness of the epoxy-impregnated layer was less than about 2 mm, and that the disc-type coil of 4 kVA or more could be feasible.
Keywords :
Epoxy resin insulation; Superconducting coils; Superconducting filaments/wires, mechanical factors; Cooling; Helium; Multifilamentary superconductors; Power generation; Superconducting cables; Superconducting coils; Superconducting filaments and wires; Temperature; Testing; Wounds;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/TMAG.1987.1065563
Filename :
1065563
Link To Document :