DocumentCode
1040917
Title
Insulators with Contaminated Surfaces, Part III: Modeling of Dry Zone Formation
Author
Woodson, Herbert H. ; Mcelroy, Alan J.
Author_Institution
Massachusetts Institute of Technology
Issue
8
fYear
1970
Firstpage
1868
Lastpage
1876
Abstract
A flat plate insulator with concentric electrodes and a fog guard is used to obtain the same qualitative behavior in leakage current and dry zone formation as a suspension insulator in a fog with horizontal wind for comparable levels of contamination and electric stress, thus demonstrating the importance of nonuniform wetting in this case. Attempts at mathematical description of the processes met with only qualitative success.
Keywords
Dielectrics and electrical insulation; Electrodes; Flashover; Geometry; Insulator testing; Laboratories; Leakage current; Stress; Surface contamination; Surface discharges;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/TPAS.1970.292771
Filename
4074271
Link To Document