• DocumentCode
    1041786
  • Title

    Benchmarking the Sandia Pulsed Reactor III cavity neutron spectrum for electronic parts calibration and testing

  • Author

    Kelly, John G. ; Griffin, Patrick J. ; Fan, Wesley C.

  • Author_Institution
    Sandia Nat. Lab., Albuquerque, NM, USA
  • Volume
    40
  • Issue
    6
  • fYear
    1993
  • fDate
    12/1/1993 12:00:00 AM
  • Firstpage
    1418
  • Lastpage
    1425
  • Abstract
    The SPR (Sandia Pulsed Reactor) III bare cavity spectrum and integral parameters have been determined with 24 measured spectrum sensor responses and an independent, detailed, transport calculation. This environment qualifies as a benchmark field for electronic parts testing. The measured SPR III cavity spectrum is characterized by a very smooth curve that predicts the measured activities with a standard deviation of 3.5% for the 24 sensors. Within the limitations of the computational model, the spectrum is also very close to that provided by MCNP (Monte Carlo Neutron Photon) calculations
  • Keywords
    calibration; electron device testing; electronic equipment testing; measurement standards; neutron effects; radiation hardening (electronics); test facilities; Monte Carlo calculation; Sandia Pulsed Reactor III; benchmark field; cavity neutron spectrum; electronic parts calibration; electronic parts testing; radiation hardness; spectrum sensor responses; transport calculation; Benchmark testing; Computational modeling; Electronic equipment testing; Inductors; Measurement standards; Monte Carlo methods; Neutrons; Optical computing; Pulse measurements; Sensor phenomena and characterization;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.273523
  • Filename
    273523